Reference No T11112830801-RE
Report No T11112830801-RE
Page 34 /
50
TEST RESULTS
Temperature
26
o
C
Humidity
46 % RH
Pressure
1029 mbar
Tested By
Vision Chang
Required Passing Performance
Transient Phenomena
Air Discharge
Test Levels Results
Test
Points
±
2 KV
±
4 KV
±
8 KV
±
12 KV
±
15 KV
Performance Criterion Pass Fail
Front A B C D
Back A B C D
Left A B C D
Right A B C D
Top A B C D
Bottom A B C D
Contact Discharge
Test Levels Results
Test
Points
±
2 KV
±
4 KV
±
6 KV
±
8 KV
±
12 KV
Performance Criterion
Pass Fail
Front A B C D
Back A B C D
Left A B C D
Right A B C D
Top A B C D
Bottom A B C D
Discharge To Horizontal Coupling Plane
Test Levels Results
SIDE OF EUT
±
2 KV
±
4 KV
±
6 KV
±
8 KV
Performance Criterion
Pass Fail
Front A B C D
Back A B C D
Left A B C D
Right A B C D
Discharge To Vertical Coupling Plane
Test Levels Results
SIDE OF EUT
±
2 KV
±
4 KV
±
6 KV
±
8 KV
Performance Criterion Pass Fail
Front A B C D
Back A B C D
Left A B C D
Right A B C D
Page view 78